fire damper是什麼意思,fire damper的意思翻譯、用法、同義詞、例句
常用詞典
n. 防火風門;防火閥;防火閘;放火擋闆;防火閘門
例句
And it can change cutting length follow to different size of fire damper optionally.
并且可以根據閥體的大小,隨意調節葉片長度,定尺切斷。
By different functions it can be categorized into smoke damper and smoke fire damper.
按其功能可分為防火閥和排煙防火閥兩大類。
8226; Product description: Automatic fire damper blade roll forming machine run by chain drive types, it can suit different production requirement.
産品說明:全自動葉片成型設備牆闆鍊條式傳動,可以適合不同企業的生産要求。
It mainly deals with the design method and principle of fire damper, positive pressure control, ventilation of stair room and running logic of HVAC in emergence situation.
正壓控制的設計原則和方法;樓梯間的通風設計以及緊急狀态下HVAC系統的運行邏輯設計。
Discusses some unclear, inconsistent or inaccurate points of fire damper installation in the related codes governing building fire protection, and offers the author's recommendations for revision.
讨論了幾個現行規範在防火閥設置問題上規定不明确、不一緻或不準确之處,提出了具體的修改建議。
專業解析
fire damper(防火風閥)是安裝在供暖、通風和空調(HVAC)系統風管或其他通風開口中的關鍵防火安全裝置。其主要功能是在火災發生時,自動關閉以阻斷火焰和高溫煙氣通過風道系統蔓延到建築物的其他區域,從而為人員疏散争取時間并減少財産損失。
核心功能與工作原理:
- 阻斷火勢蔓延: 當火災産生的熱量達到預設溫度(通常為165°F或74°C)時,fire damper中的易熔合金鍊接或熱敏元件會熔化或動作。
- 自動關閉: 該動作觸發閥門内的彈簧機構或重力裝置,使防火擋闆(通常由鍍鋅鋼闆等耐火材料制成)迅速關閉。
- 維持耐火完整性: 關閉後的防火閥與其安裝所在的防火牆或防火分隔具有相同的耐火等級(如1小時、1.5小時、3小時),能在規定時間内阻止火焰穿透和高溫煙氣通過。
主要類型:
- 靜态防火閥: 最常見類型,僅依靠溫度感應自動關閉。一旦關閉,在火災後需手動複位。
- 動态防火閥: 設計用于在氣流或系統壓力存在時也能有效關閉,常用于風機運行或正壓/負壓區域。
- 組合防火/防煙閥: 結合了防火閥和防煙閥的功能,既能阻斷火焰和高溫,也能在火災初期阻止冷煙氣的滲透。
應用與規範:
防火風閥是建築規範強制要求的關鍵消防部件,其設計、安裝、測試和維護需嚴格遵守相關标準,例如:
- 國際規範: 國際建築規範(IBC)和國際消防規範(IFC)明确規定了防火閥在防火牆、防火分區貫穿處的設置要求。
- 測試标準: 在美國,防火閥需通過UL 555标準認證,确保其耐火性能和可靠性。
- 安裝與維護: 美國國家消防協會标準NFPA 80(防火門及其他開孔保護裝置标準)和NFPA 105(防煙門及其他開孔保護裝置标準)詳細規定了防火閥、防煙閥及其組合閥的安裝、檢查和維護要求。
權威參考來源:
- NFPA 90A: Standard for the Installation of Air-Conditioning and Ventilating Systems - 美國國家消防協會關于暖通空調系統安裝的标準,涵蓋防火閥要求。 https://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=90A
- International Building Code (IBC), Chapter 7: Fire and Smoke Protection Features - 國際建築規範中關于防火分隔和貫穿封堵的要求。 https://codes.iccsafe.org/content/IBC2021P1/chapter-7-fire-and-smoke-protection-features
- UL 555: Standard for Fire Dampers - Underwriters Laboratories 的防火閥安全認證标準。 https://standardscatalog.ul.com/ProductDetail.aspx?productId=UL555
- NFPA 80: Standard for Fire Doors and Other Opening Protectives &NFPA 105: Standard for Smoke Door Assemblies and Other Opening Protectives - 涵蓋防火閥、防煙閥及其組合閥的安裝、檢查與維護。 https://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=80 | https://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=105
Fire damper是建築被動消防系統的重要組成部分,通過自動關閉風道來維持防火分隔的完整性,有效阻止火勢和煙氣通過通風系統擴散,對保障生命安全和減少火災損失至關重要。其選型、安裝和維護必須嚴格遵循國家及國際的建築與消防規範。
網絡擴展資料
“Fire damper”是建築消防系統中的專業術語,指防火閥,主要用于通風和空調系統的管道中,在火災時阻斷火勢蔓延。以下是詳細解釋:
1.定義與核心功能
- 基本作用:防火閥安裝在通風或空調系統的送/回風管道上,平時保持開啟狀态,火災時當管道内溫度達到特定阈值(70℃或280℃)會自動關閉,阻止煙霧和火焰擴散,同時滿足一定時間的耐火完整性要求。
- 組成部件:通常由閥體、葉片、溫感器及執行機構構成,部分型號可能配備消防聯動模塊。
2.分類與工作場景
根據用途和觸發溫度,主要分為兩類:
- 普通防火閥(70℃型):用于通風/空調系統,溫度達70℃關閉,防止火勢通過管道蔓延。
- 排煙防火閥(280℃型):安裝在機械排煙系統管道,火災初期開啟排煙,當煙氣溫度升至280℃時關閉,避免高溫加劇火勢。
3.與其他閥門的區别
- 排煙閥(Smoke Damper):平時關閉,火災時手動或電動開啟,主要用于排出煙霧。
- 調節功能擴展:部分防火閥帶有風量調節功能(如FVD型),或支持遠程電動控制(如BSFVD型)。
4.應用規範
- 安裝位置:常見于風管穿越防火牆、變形縫處,或排煙系統支管末端。
- 聯動要求:部分場景需連接消防模塊,實現與風機、報警系統的自動聯動控制。
附:術語來源
“Fire damper”為英文直譯,其中“damper”在工程中表示調節氣流/液流的閥門或擋闆。需注意與“fire damp”(沼氣)等易混淆詞彙區分。
别人正在浏覽的英文單詞...
walljailstomachget in the waypinocchioavivfamishedgladiolusmislabeledOedipusregulatorsunpurifiedfragment length polymorphismfrom amonggeological environmentheat conductioninvolvement intemperature differencewest ofbayberryBoreasepipterygoidhelispotheterosporyhydatidiliacjammylaminatorLappLebaycid