[熱] 火把煙囪
Vent all waste hydrogen through a flue or flare stack.
通過煙道或火把煙筒排出所有廢氫。
Flush system with hydrogen until required purity is reached. Vent all waste hydrogen through a flue or flare stack.
用氫沖洗設備,直到達到所要求的純度。通過煙道或火把煙筒排出所有廢氫。
This paper introduces the composition, safety design and safety factors necessary to be taken into consideration for venting and flare stack system.
介紹放空火炬系統的組成、安全設計及要考慮的安全因素。
Offsite flare headers, from the blinding location downstream of process unit knockout drums to the base of the flare stack, shall be pneumatically tested per the applicable Code.
外照明标題,從下遊的緻盲位置過程股鼓敲除的基礎火炬,應氣動測試每適用的守則。
This unit mainly supplies fuel gas for the equipment like in-plant boiler house heater in dehydration unit main combustion furnace in sour gas treatment unit tail gas incinerator and flare stack etc.
本單元主要為廠内鍋爐房、脫水裝置加熱爐、酸氣處理裝置主燃燒爐、尾氣灼燒爐以及放空火炬等燃氣設備提供燃料氣。
在石油化工和能源工業領域,"flare stack"(火炬煙囪)是指用于安全燃燒處理廢氣的專用燃燒裝置。它由直立鋼制煙囪、燃燒器頭、點火系統及輔助設備組成,主要功能是通過可控燃燒将生産過程中無法回收的烴類氣體轉化為二氧化碳和水蒸氣,既保障工業安全又降低環境污染。
根據美國環境保護署(EPA)的技術文件,現代火炬系統需滿足嚴格燃燒效率标準,通常要求燃燒後烴類去除率達到98%以上。其工作原理遵循熱氧化反應公式:
$$ C_xH_y + left( frac{3x}{2} + frac{y}{4} right)O_2 rightarrow xCO_2 + frac{y}{2}H_2O $$
國際标準化組織ISO 23551系列标準規定了火炬系統的設計規範,強調需根據氣體流量、熱值等參數計算煙囪高度,确保火焰穩定性和輻射安全距離。英國能源研究所(EI)的研究報告指出,海上平台使用的封閉式火炬系統通過蒸汽輔助燃燒技術,可将可見煙霧減少90%以上。
在煉油廠緊急洩壓場景中,火炬系統能瞬時處理數萬立方米氣體,其設計需符合API 537标準中關于最大允許背壓和洩放效率的要求。全球知名工程公司Fluor的技術手冊顯示,先進的分級燃燒技術可使火炬系統氮氧化物排放量低于25ppm。
“Flare stack”是一個工業領域專業術語,具體解釋如下:
指一種用于安全燃燒工業廢氣的直立煙囪裝置,常見于石油化工、煉油廠等場所。其核心作用是通過燃燒處理生産過程中産生的易燃或有害氣體,防止直接排放造成環境污染或安全隱患。
火炬煙囪、廢氣燃燒塔(中文);Flare tower、Gas flare(英文)。